Agar Scientific specialises in producing a wide range of specimens specifically for SEM test and calibration where quantification or high resolution results are required.

 

SEM resolution is tested in terms of a combination of criteria, namely resolved gaps and the number of grey levels in the image. This is to ensure that the resolution has not been distorted by using the contrast to maximise visibility of edges. High resolution images ideally should show fine detail together with a lack of noise, evidenced by a good range of grey levels.

For assessments of resolution in scanning electron microscopes, we have developed a range of gold on carbon and tin on carbon test specimens. These specimens are suitable for tests of SE and BSE imaging and also for chemical mapping in high resolution systems such as in Auger scanning instruments. The specimens can be supplied on most types of specimen stub.

Filtered (1)
QUICK BUY

4 products available

You've viewed 4 of 4 products

  1. Geller Reference Standard MRS-3
    The MRS-3 is a universal magnification calibration standard suitable for a wide range of instrumentation. Magnifications from 10X to 50,000X. 2µm minimum pitch. Traceable to national labs for ISO9000 and ISO17025.
    Average lead time: 1 to 28 days

    POA

    Average lead time: 1 to 28 days
  2. Geller Reference Standard MRS-4
    A fifth Generation, high magnification reference standard for instrument calibration from 10X to 200,000X (1/2µm minimum pitch). NIST and NPL traceable for ISO9000 and ISO17025.
    Average lead time: 28 days

    POA

    Average lead time: 28 days
  3. Geller Reference Standard MRS-6
    A fifth generation Magnification Reference Standard & Stage Micrometer for instrument calibration from 1,500X to 1,000,000X (80nm minimum pitch). NIST and NPL traceable for ISO9000 and ISO17025.
    Average lead time: 28 days
    Average lead time: 28 days
  4. Geller reference standard re-callibration service
    Geller MicroAnalytical magnification standards can be cleaned and re-certified to assure continued use as a traceable standard.
    Average lead time: 19 days

    POA

    Average lead time: 19 days
Filtered (1)
QUICK BUY

4 products available

You've viewed 4 of 4 products

PRICE & AVAILABILITY: Please note that while we are working closely with our suppliers to minimise any global supply chain issues, prices and availability may be subject to change at short notice.
FILTERS
VIEW 4 PRODUCTS Cancel